Why your doorbell transformer keeps burning out

Replacing the same part twice is infuriating, and it is also the clue. The second one probably didn't fail for the same reason as the first. Something else is still wrong, and the checks below will usually find it. The first one is just reading the label on the transformer, so it costs nothing to start.

Some links below are affiliate links. Buy through one and we earn a small commission, at no extra cost to you.

Check this before you buy anything

If it burned out with the doorbell disconnected, stop reading about sizing. A transformer that fails with nothing attached has a short somewhere in the wiring, and a bigger one will just push more current into it.

Disconnect the doorbell and wait

Take the camera off the wiring entirely and leave the transformer powered for a day. If it still gets hot, hums badly or trips, the fault is in the wiring and the rating is a red herring. Skip to the short-circuit section.

Read what is printed on the transformer

It will state a voltage and either a VA rating or an amperage. Volts multiplied by amps gives you VA. This one number decides everything that follows, and it is usually stamped on the body or on a small label beside the terminals.

Compare it against what your doorbell asks for

The requirement is set by the model, and the spread across one brand is wide. Check the figures below against the printed rating before you buy anything.

The two figures that matter sit on the secondary line. Volts must fall inside your model’s published band; VA is how much the transformer can supply.
Doorbell transformer mounted on a wall, wired to a doorbell camera
Transformer

Newhouse Hardware 16V 30VA doorbell transformer

A plain hardwired transformer at 16 volts and 30VA. That is the band most wired doorbell cameras ask for, and well above the 10VA a chime-era transformer supplied. Match your own model's published range on both numbers, volts and VA. More is not automatically safer. Mount it on the outside of a junction box and never inside a wall cavity: the manufacturer is explicit that it needs air around it to shed heat.

Doorbell transformer mounted on a wall beside a doorbell camera
Transformer

BOJACK 16V 30VA transformer

The same 16V 30VA specification in a different body, listed for doorbell and thermostat use. Worth knowing because transformer listings come and go constantly and having a second known-good option saves a rebuild when one goes out of stock.

Non-contact voltage tester glowing beside a doorbell transformer
Test gear

KAIWEETS non-contact voltage tester

Tells you whether a wire is live without touching a terminal. The dual range is the reason to pick this one. Doorbell wiring is low voltage and the transformer's mains side is not, so a tester that only sees line voltage reads a live doorbell wire as dead. The low range is not automatic: press the sensitivity button to reach it. Understand what it is before you buy it. It cannot read a voltage or a VA figure. It tells you a transformer is powered and nothing about whether it is big enough. That question needs a meter.

Test gear glyph for AstroAI true-RMS auto-ranging multimeter
Test gear

AstroAI true-RMS auto-ranging multimeter

The tool the transformer pages send you to. It reads AC volts across the two low-voltage terminals. That is the measurement telling you what arrives at the doorbell, rather than what a label printed years ago claims. Auto-ranging means you do not have to pick a scale before you know the answer. One limit: no meter reads VA directly. VA is a rating, not a measurement, so it comes off the transformer's plate while the meter tells you whether the voltage holds up.

If the old one was genuinely undersized for your model, yes, and stay inside the published range for that model. A larger VA rating does not force more current into the doorbell; the doorbell draws what it needs. What a bigger transformer will not fix is a short, and it can make one worse.
Not automatically. Both sit inside the range for most current models, and the VA rating matters more than the voltage. Going above the published maximum is how you damage the doorbell or the chime rather than the transformer.
Warm is normal. Too hot to keep a hand on is not, and neither is a change you can date to the day the camera went in.
Entirely, if you leave them on battery and never wire them in. That is a real option and it is the right answer for a lot of houses, particularly rented ones.